Lutz Durchflussmesser, Durchflusszähler MDO 2
PREIS ANFRAGEN
Please enter these characters in the following text field.

Mit * gekennzeichnete Felder sind Pflichtfelder.
LUTZ PUMPS, INC. | USA
Family business since 1954
info@lutzpumpsamerica.com
800 8 43 39 01 (toll free)
Flow Meter MDO 2

Flow Meter MDO 2

for mineral oils and alternative fuels

Preis anfragen
Please enter these characters in the following text field.

Mit * gekennzeichnete Felder sind Pflichtfelder.
  • US-0211-610
  • upon request
  • is also suitable for rapeseed and vegetable oils
Description: The flow meter with display impresses with its simple, demand-oriented...more
Product information "Flow Meter MDO 2"

Description:

The flow meter with display impresses with its simple, demand-oriented display, operability and compact design. Due to the rotating Oval gear meter and a magnet integrated in the measuring chamber, it enables the exact measurement of the volume flow and measures mineral oils and alternative fuels  precisely, quickly and above all efficiently. 

  • Suitable for measuring alternative fuels

Features & Advantages

  • Measurement according to the oval wheel principle
  • High measuring accuracy
  • Low pressure losses in the system
  • Measuring range from 3 l/min - 80 l/min
  • Low frictional resistance
Technical data
▼ MEDIUM ▼
Suitable media: Diesel (<40°C) , Heizöl, Hydrauliköl, Maschinenöl, Motoröl
▼ WERKSTOFFE | MATERIAL | MATERIAAL ▼
Housing Material: Aluminum
Seals (material): FPM (fluorinated rubber)
Measuring wheels (material): LCP
▼ FÖRDERDATEN | OPERATING DATA | SPECIFICATIES ▼
Flow volumes (up to max. GPM): 21
Temperature of medium (max °F): 176
Operating pressure (max. psi): 58
Viscosity (up to max. cps)*: 1000
▼ DURCHFLUSSZÄHLER | FLOW METER | FLOWMETERS ▼
Messprinzip: Ovalrad
Connection: Gewinde
External connection thread : 1 1/4"
Messgenauigkeit kalibriert**: ± 0,5
▼ EIGENSCHAFTEN | PROPERTIES | EIGENSCHAPPEN ▼
Connection: Gewinde
Protection type: IP67
Version: ohne Mengenvorwahl
Type: MDO 2

* The maximum flow rate is a value determined by means of a test bench and measured with water at a medium temperature of approx. 20 °C. The measurement is carried out at the pressure joint of the pump, without hose, nozzle or flow meter. The achievable flow rate in use is lower and depends on the individual application, the liquid properties and the configuration of the pump. The max. delivery head also depends on the pump design, motor and fluid. The viscosity values are determined with oil.

** Test assembly: Medium water / diesel, flow in preferred direction, settling section 0.2 m upstream and downstream of flow meter

Service & Support