Notice: The nominal size of the flow meter is DN 8.
Description:
The flow meter is a compact basic meter with a connection cable and plug for a connection to an external control unit. Due to the rotating Oval gear meter and the magnets placed on the measuring wheels, it enables the accurate measurement of the volume flow, measuring thin-bodied to highly viscous media such as acids, alkalis, mineral oils, hydrocarbons and solvents precisely, quickly and, above all, efficiently.
- Media examples: Paints, lacquers, mineral oils, acids, alkalis
Features & Advantages
- Measurement according to the oval wheel principle
- High measuring accuracy due to overrun correction
- Low pressure losses in the system
- Touchscreen display with self-explanatory, multilingual user interface
- Measuring range from 0.25 l/min - 8.3 l/min
- Low frictional resistance
Housing Material: | Edelstahl (1.4571) |
Seals (material): | FPM (fluorinated rubber) |
Measuring wheels (material): | Edelstahl (1.4571) |
Axis (material): | Edelstahl (1.4571) |
Flow volumes (up to max. GPM): | 2,2 |
Temperature of medium (max °F): | 176 |
Operating pressure (max. psi): | 232 |
Viscosity (up to max. cps)*: | 1000 |
Messprinzip: | Ovalrad |
Connection: | Gewinde |
Hose connection - nominal diameter (DN): | 8 |
Messgenauigkeit kalibriert**: | ± 2,5 |
Wiederholgenauigkeit (%): | ± 0,03 |
Connection: | Gewinde |
Version: | ohne Mengenvorwahl |
Type: | HDO 080 Niro/Niro |
* The maximum flow rate is a value determined by means of a test bench and measured with water at a medium temperature of approx. 20 °C. The measurement is carried out at the pressure joint of the pump, without hose, nozzle or flow meter. The achievable flow rate in use is lower and depends on the individual application, the liquid properties and the configuration of the pump. The max. delivery head also depends on the pump design, motor and fluid. The viscosity values are determined with oil. ** Test assembly: Medium water / diesel, flow in preferred direction, settling section 0.2 m upstream and downstream of flow meter